Standard Impression Coping Screw

Send Inquiry
Standard Impression Coping Screw
Details
The Standard Impression Coping Screw is a dedicated precision fastening component engineered for use with compatible dental implant impression copings during conventional impression-taking procedures. It securely fastens the coping to the corresponding implant fixture or prosthetic connection, ensuring dimensional stability and preventing micro-movement throughout the transfer phase.
Category
Impression Coping Screw
Share to
Description

The Standard Impression Coping Screw is a dedicated precision fastening component engineered for use with compatible dental implant impression copings during conventional impression-taking procedures. It securely fastens the coping to the corresponding implant fixture or prosthetic connection, ensuring dimensional stability and preventing micro-movement throughout the transfer phase.

 

For implant manufacturers, component distributors, and OEM buyers, seamless integration relies on strict adherence to thread geometry, pitch accuracy, engagement length, and driver interface compatibility.

 

Technical Specifications

 

Parameter

Specification Details

Product Type

Standard Impression Coping Screw

Part Number / SKU

ICS-SCR-1408

Compatible Coping

Standard Open-Tray / Closed-Tray Impression Copings (Series ICS-35)

Compatible Implant / Abutment System

Internal Hex Platform (Standard Regular Platform)

Connection Type

Internal Hex Connection

Thread Diameter & Pitch

M1.4 x 0.35 mm

Overall Length

12.50 mm (Thread length: 4.50 mm)

Screw-Head Geometry

Flat Head with Controlled Seating Angle

Driver Interface

1.22 mm Hex Socket

Material Grade

Titanium Alloy Ti-6Al-4V ELI (ASTM F136 / ISO 5832-3)

Surface Finish / Treatment

Acid-cleaned, Passivated, Ultrasonic Degreased

Packaging Condition

Non-sterile, individual blister pack or bulk option

Minimum Order Quantity (MOQ)

50 pieces per batch (Sample quantities available upon request)

OEM / ODM Customization

Available upon technical review of customer drawings or reference samples

 

Precision & Engineering Highlights

 

Strict Dimensional Tolerance: Micro-machined to exact tolerances to ensure optimal engagement with internal/external implant connections and prevent thread stripping under torque.

 

Optimized Driver Engagement: Designed with precise internal or external driver interfaces (such as hex or torx) for secure torque transmission during clinical application.

 

Controlled Surface Integrity: Cleaned and finished to minimize surface contaminants and ensure smooth insertion and removal performance.

 

Target Applications & Sourcing Scenarios

 

Conventional Impression Procedures: Used alongside compatible impression copings to securely anchor components during clinical transfer procedures.

 

Prosthetic Component Distribution: Integrated into distributor portfolios as reliable, high-precision replacement screws for established implant platforms.

 

OEM & Private-Label Manufacturing: Customized production for implant system developers based on engineering drawings, strict material specifications, and quality standards.

 

How to Select and Order the Correct Screw

 

Identify Mating Components: Provide the impression coping part number, technical drawing, or clear reference photos.

 

Confirm Implant Connection: Specify the exact implant or abutment platform and connection type.

 

Verify Critical Dimensions: Supply thread specifications, overall length, head profile, and driver interface.

 

Define Material Standards: State your required material grade and specific surface treatment.

 

Specify Quality & Compliance: Confirm dimensional tolerance standards, material documentation, and traceability needs.

 

Outline Order Volume: Indicate sample quantities, pilot batch size, and projected annual demand.

 

Manufacturing Quality & Verification

Dimensional Inspection

Verification of critical tolerances against approved drawings.

Thread Integrity

Optical and mechanical checks of thread profile and mating fit.

Material Traceability

Mill test certificates and material grade verification.

Surface Cleanliness

Visual inspection and finish compliance criteria.

Batch Lot Control

Complete lot identification records supporting strict supply chain tracking.

 

Frequently Asked Questions

 

Q: Is this screw compatible with all dental implant systems?

A: No universal compatibility is assumed. Thread dimensions, screw-head shapes, lengths, and driver interfaces vary across implant brands. Always confirm compatibility using your part number, drawing, or sample.

Q: Can I order the impression coping screw separately from the coping?

A: Yes. Separate-component supply is available depending on current product configurations. Please explicitly state that you require the screw only when submitting your inquiry.

Q: What information is required to get an accurate quotation?

A: To ensure a prompt and accurate response, please provide the part number, compatible implant system, technical drawings or reference samples, required order volume, and any special material or inspection requirements.

Q: Can you manufacture custom screws based on our engineering drawings?

A: Yes. OEM/ODM services are supported subject to technical feasibility reviews of your drawings, material requirements, tolerance standards, and production volumes.

Q: What quality documentation can be provided?

A: Depending on the order, material test certificates, dimensional inspection reports, and batch traceability records can be provided. Please specify your documentation requirements prior to ordering.

Hot Tags: standard impression coping screw, China standard impression coping screw manufacturers, suppliers, Implant GBR Drills, implant torque driver, leaf tissue punch, straumann implant torque wrench, titanium mesh dental bone graft, tooth care accessories

Send Inquiry